Single station


<< Click to show table of contents >>

Navigation:  Toolbox objects > Processes >

Single station


Contents

1. Brief Description

2. Operation and Control Description

3. Parametrization

 

 

1. Brief Description

The Single Station object is used to machine parts at a single machining station.

 

2. Operation and Control Description

The single-station cell receives a single workpiece from its predecessor, processes it, and, once the setup and processing times have elapsed, passes it on in sequence to one of its successors.

If the incoming workpiece types are not identical—that is, if they do not have the same name—the single-station cell must be set up for that workpiece type in order to process it.

While a work order is at the single-station cell, it does not accept any newly arriving work orders but instead adds them to its hold list.

Only after it becomes available again does it accept the held work orders in sequence and process them. If the single-station cell has multiple successors, it transfers the work orders to them in sequence.

If the successor to which the part is to be transferred is blocked—i.e., full or malfunctioning—the individual station does not select another available successor to which it can transfer the part.

Instead, it does not transfer the part and thus becomes blocked.

Only after the successor is free and no longer blocked does it transfer the part and become unblocked. You can also define a different transfer behavior in a method.

 

3. Parametrization

20260724_objektparameter_alle_EN

Figure 1 - Single Station

Parameter

Required

Description

Name

no

Name des Objektes

Processing time

no

The time during which the MU remains on the object for processing. It refers to the time interval between setup for this MU type and the point in time at which it transfers the material flow object to its successor.

Set-up time

no

The time it takes to set up the object for processing a different MU type.

Setup After Number of Parts

yes

Number of parts that must enter the station for station setup to begin

Availability

yes

Station availability in %

MTTR

no

Mean Time To Repair

Exit strategy

yes

Cyclical: MUs are transferred cyclically to successors according to the sequence,

Start at Successor 1: MUs are always transferred to the successor of the object with edge number 1

Comment

no

Text field for comments on the object

 

 


© SimPlan AG - Hanau District Court, Commercial Register (Part B) 6845 - info@simplan.de - www.simplan.de/en